IONIZING RADIATION DETECTION ALGORITHM FOR CMOS SENSOR FROM CONSUMER CAMERA DEVICE

  • Megat Harun Al Rashid Megat Ahmad1 Puspati ION Technology Solution
  • Nashihah Ab Karim Agensi Nuklear Malaysia
  • Lahasen@Normanshah Dahing Agensi Nuklear Malaysia
  • Hearie Hassan Agensi Nuklear Malaysia
  • Suhairy Sani Agensi Nuklear Malaysia
  • Ismail Mustapha Agensi Nuklear Malaysia
  • Nor Pa’iza Mohamad Hasan, Dr. Agensi Nuklear Malaysia
  • Shaharuddin Sayuti Agensi Nuklear Malaysia
Keywords: Laplacian of gaussian, CMOS, ionizing radiation, sensor

Abstract

Abstract

Laplacian of Gaussian (LoG) algorithm was evaluated to quantify ionizing gamma events on CMOS sensor in a consumer webcam. The ionizing events measurements were carried out by fully covering the CMOS sensor with aluminum foil thus allowing only gamma photons to reach the CMOS sensor. The CMOS operation was done by recording movie of ionizing events with 241Am as gamma radiation source. LoG algorithm was then applied on the movie file frame by frame. The LoG algorithm was found capable to discriminate cluster of bright pixels with values that were assumed to correspond to charge collection for each individual ionizing event. The very thin layer of the CMOS however made it difficult to build gamma spectrum because of low ionizing energy deposition.

 

Abstrak

Algoritma pengoperasian Laplace ke atas Gauss (LoG) telah dinilai sebagai algoritma pengiraan untuk mengira bilangan kejadian pengionan gamma pada pengesan CMOS di dalam kamera web barangan konsumer. Pengukuran kejadian pengionan dilaksanakan dengan menutup sepenuhnya pengesan CMOS dengan kerajang aluminium supaya hanya foton gamma sahaja yang boleh sampai ke pengesan CMOS. Operasi CMOS dilakukan dengan merakam filem kejadian pengionan dengan 241Am sebagai sumber radiasi gamma. Algoritma LoG kemudiannya digunakan ke atas fail filem tersebut bingkai ke bingkai. Algoritma LoG didapati berupaya mengenalpasti kelompok dengan piksel cerah yang nilainya sepadan dengan pengumpulan cas bagi setiap kejadian pengionan. Namun begitu, lapisan CMOS yang sangat nipis menyukarkan pembangunan spektrum gamma yang berdasarkan jumlah nilai pengumpulan cas ini.

Author Biographies

Megat Harun Al Rashid Megat Ahmad1, Puspati ION Technology Solution

Puspati ION Technology Solution (PITS),
Lorong Villa Gemilang, Kampung Sungai Buah Dalam,
43800 Dengkil, Selangor, Malaysia

Nashihah Ab Karim, Agensi Nuklear Malaysia

NDT-Material Structural Integrity (NDT-MSI),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Lahasen@Normanshah Dahing, Agensi Nuklear Malaysia

Plant Assessment Technology (PAT),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Hearie Hassan, Agensi Nuklear Malaysia

Plant Assessment Technology (PAT),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Suhairy Sani, Agensi Nuklear Malaysia

NDT-Material Structural Integrity (NDT-MSI),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Ismail Mustapha, Agensi Nuklear Malaysia

NDT-Material Structural Integrity (NDT-MSI),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Nor Pa’iza Mohamad Hasan, Dr., Agensi Nuklear Malaysia

Plant Assessment Technology (PAT),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Shaharuddin Sayuti, Agensi Nuklear Malaysia

NDT-Material Structural Integrity (NDT-MSI),
Industrial Technology Division,
Agensi Nuklear Malaysia,
43000 Kajang, Selangor, Malaysia

Published
2023-06-30
How to Cite
Megat Ahmad1M. H. A. R., Ab Karim, N., Dahing, L., Hassan, H., Sani, S., Mustapha, I., Mohamad Hasan, N. P., & Sayuti, S. (2023). IONIZING RADIATION DETECTION ALGORITHM FOR CMOS SENSOR FROM CONSUMER CAMERA DEVICE. JOURNAL of NUCLEAR and Related TECHNOLOGIES, 20(01), 1-6. Retrieved from http://jnrtmns.net/index.php/jnrt/article/view/224
Section
Articles