AN OVERVIEW OF X-RAY MICRO COMPUTED TOMOGRAPHY (MICRO-CT) APPLICATION AT THE MALAYSIAN NUCLEAR AGENCY

  • Roslan Yahya, Dr. Malaysian Nuclear Agency
  • Mohd Fitri Abdul Rahman, Dr. Malaysian Nuclear Agency
  • Lahasen @ Normanshah Dahing Malaysian Nuclear Agency
  • Nazrul Hizam Malaysian Nuclear Agency
  • Azhani Mohd Razali Malaysian Nuclear Agency
  • Khairiah Yazid @ Khalid Malaysian Nuclear Agency
  • Maziah Jamaludin Malaysian Nuclear Agency
  • Hearie Hassan Malaysian Nuclear Agency
Keywords: X-ray micro computed tomography, non-destructive imaging technique, defect detection

Abstract

Abstract

This technical paper provides an overview of the applications of X-ray Micro Computed Tomography (Micro-CT), with a specific focus on Skyscan 1172 Micro-CT, at the Malaysian Nuclear Agency. Micro-CT is a non-destructive imaging technique that has gained widespread use in scientific and industrial fields. The paper examines the fundamental principles and techniques of Skyscan 1172 Micro-CT and explores its applications in the Malaysian Nuclear Agency for material characterization and defect detection. Additionally, the paper discusses the advantages and limitations of Micro-CT and outlines the challenges and opportunities for its use in Malaysia. Overall, this review aims to provide insights into the potential applications of Micro-CT in Malaysia and to encourage further research and development in this field.

Abstrak

Kertas teknikal ini memberikan gambaran keseluruhan aplikasi X-ray Micro Computed Tomography (Micro-CT), dengan fokus khusus pada Skyscan 1172 Micro-CT, di Agensi Nuklear Malaysia. Micro-CT adalah teknik pengimejan yang tidak merosakkan yang telah mendapat penggunaan meluas dalam bidang saintifik dan perindustrian. Kertas kerja ini mengkaji prinsip dan teknik asas Skyscan 1172 Micro-CT dan meneroka aplikasinya dalam Agensi Nuklear Malaysia untuk pencirian material dan kecacatan Selain itu, kertas kerja ini membincangkan kelebihan dan batasan Micro-CT dan menggariskan cabaran dan peluang untuk kegunaannya di Malaysia. Secara keseluruhan, ulasan ini bertujuan untuk memberikan pandangan tentang potensi aplikasi Micro-CT di Malaysia dan untuk menggalakkan penyelidikan dan pembangunan selanjutnya dalam bidang ini.

Author Biographies

Roslan Yahya, Dr., Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Mohd Fitri Abdul Rahman, Dr., Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Lahasen @ Normanshah Dahing, Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Nazrul Hizam, Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Azhani Mohd Razali, Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Khairiah Yazid @ Khalid, Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Maziah Jamaludin, Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Hearie Hassan, Malaysian Nuclear Agency

Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Published
2023-12-31
How to Cite
Yahya, R., Abdul Rahman, M. F., Dahing, L. @ N., Hizam, N., Mohd Razali, A., Khalid, K. Y. @, Jamaludin, M., & Hassan, H. (2023). AN OVERVIEW OF X-RAY MICRO COMPUTED TOMOGRAPHY (MICRO-CT) APPLICATION AT THE MALAYSIAN NUCLEAR AGENCY. JOURNAL of NUCLEAR and Related TECHNOLOGIES, 20(02), 1-6. Retrieved from http://jnrtmns.net/index.php/jnrt/article/view/231
Section
Articles