NEUTRON FLUX MEASUREMENTS IN THE ROTARY RACK OF THE REAKTOR TRIGA PUSPATI

  • Norfarizan Mohd Said
  • Na’im Syauqi Hamzah
  • Hasniyati Md Radzi
  • Adam Haziq
  • Julia Abdul Karim, Dr Malaysian Nuclear Agency (Nuclear Malaysia)
Keywords: neutron flux measurement, TRIGA PUSPATI, rotary rack, reactor technology

Abstract

ABSTRACT

Neutron flux is an essential parameter in evaluating the performance of research reactors. The neutron flux distribution in the core region of the Reaktor TRIGA PUSPATI (RTP) has been measured through the neutron activation analysis method, using bare and cadmium covered gold wires activation. The aim of the measurement is to determine the neutron flux in the rotary rack at the end-of-cycle (EOC) RTP core-15. The wires were irradiated in the rotary specimen rack with the reactor operated at 750 kW. The gamma activities of the wires are measured by using high-purity germanium (HPGe) gamma detector.

 ABSTRAK

Fluks neutron merupakan parameter penting dalam penilaian prestasi sesebuah reaktor penyelidikan. Taburan fluks neutron terma di dalam teras Reaktor TRIGA PUSPATI (RTP) diukur melalui teknik analisis pengaktifan neutron menggunakan pengaktifan wayar emas dan wayar emas dilindungi rod kadmium.  Objektif pengukuran ini ialah menentukan nilai fluks neutron di rak berputar di penghujung kitaran konfigurasi teras RTP yang ke-15. Eksperimen dijalankan di fasiliti penyinaran rak berputar dengan kuasa reaktor 750 kW. High-Purity Germanium (HPGe) Gamma Detector digunakan untuk pengukuran aktiviti gamma wayar yang disinarkan.

 

Author Biographies

Norfarizan Mohd Said

Reactor Technology Centre, Technical Support Division,
Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Na’im Syauqi Hamzah

Reactor Technology Centre, Technical Support Division,
Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia

Hasniyati Md Radzi

Reactor Technology Centre, Technical Support Division,
Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Adam Haziq

Reactor Technology Centre, Technical Support Division,
Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia.

Julia Abdul Karim, Dr, Malaysian Nuclear Agency (Nuclear Malaysia)

Reactor Technology Centre, Technical Support Division,
Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor, Malaysia

Published
2022-11-30
How to Cite
Mohd Said, N., Hamzah, N. S., Md Radzi, H., Haziq, A., & Abdul Karim, J. (2022). NEUTRON FLUX MEASUREMENTS IN THE ROTARY RACK OF THE REAKTOR TRIGA PUSPATI. JOURNAL of NUCLEAR and Related TECHNOLOGIES, 19(02), 8-15. Retrieved from https://jnrtmns.net/index.php/jnrt/article/view/215
Section
Articles