IMPACT OF FOCAL SPOT SIZE ON FILM IMAGE QUALITY BY USING YXLON Y.XMB 225 X-RAY SYSTEM: A COMPARATIVE STUDY

  • Amer Hazreq Haron Malaysian Nuclear Agency, Selangor, Malaysia.
Keywords: non-destructive testing, film quality, x-ray imaging

Abstract

ABSTRACT 

Non-destructive testing (NDT) is a technique used to detect flaws in structures, with X-ray machines being a key component. An experiment was conducted to investigate the impact of different focal spot sizes on film quality and contribute to more efficient NDT methods. Results showed that smaller focal spot sizes produced sharper, more detailed images, while larger ones produced slightly softer and less detailed images. The study emphasizes the importance of aligning the choice of focal spot size with specific imaging requirements and material properties. 

ABSTRAK 

Ujian tanpa musnah (NDT) ialah teknik yang digunakan untuk mengesan kecacatan dalam struktur, dengan mesin sinar-X menjadi komponen utama. Satu eksperimen telah dijalankan untuk menyiasat kesan saiz titik fokus yang berbeza terhadap kualiti filem dan menyumbang kepada kaedah NDT yang lebih cekap. Keputusan menunjukkan bahawa saiz titik fokus yang lebih kecil menghasilkan imej yang lebih tajam, lebih terperinci, manakala yang lebih besar menghasilkan imej yang lebih lembut dan kurang terperinci. Kajian ini menekankan kepentingan menyelaraskan pilihan saiz titik fokus dengan keperluan pengimejan khusus dan sifat bahan.

Published
2025-01-05
How to Cite
Haron, A. H. (2025). IMPACT OF FOCAL SPOT SIZE ON FILM IMAGE QUALITY BY USING YXLON Y.XMB 225 X-RAY SYSTEM: A COMPARATIVE STUDY. JOURNAL of NUCLEAR and Related TECHNOLOGIES, 21(1 & 2), 49-56. Retrieved from https://jnrtmns.net/index.php/jnrt/article/view/256