Neutron spectrometry of thermal column by various filter/moderating materials at reactor TRIGA PUSPATI for BNCT research
Abstract
ABSTRACT
Thermal neutron beam from thermal column was selected for a Boron Neutron Capture Therapy (BNCT) system utilizing the Malaysian TRIGA MARK II reactor. Determination of shielding materials for fast and epithermal neutron was conducted. The materials selected were polyethylene, paraffin and water. For gamma-ray shielding, lead was used. The objective of this paper is to present the simulation and verification of an optimal design of BNCT collimation at a beam line viewing the thermal column. A collimator was made from polyethylene pipe with 8 cm of diameter filled with paraffin.
ABSTRAK
Neutron terma merupakan neutron yang serasi untuk sistem ‘Boron Neutron Capture Therapy’ (BNCT) yang menggunakan reaktor TRIGA Malaysia MARK II. Penentuan dan bahan-bahan untuk neutron puasa dan epithermal telah dijalankan. Bahan-bahan yang dipilih ialah polietilena, dihadiri oleh penyelidik bagi dan air. Bagi melindungi sinar gamma, plumbum yang digunakan. Objektif kertas kerja ini adalah untuk membentangkan simulasi dan pengesahan Reka bentuk BNCT collimation yang optimum pada garisan pancaran yang melihat tiang haba. Collimator yang telah dibuat dari paip polietilena dengan 8 cm diameter yang dipenuhi dengan dihadiri oleh penyelidik bagi.Keywords: composite, thermography, rad-waste, impact strength.